Comparison between Different Control Strategies of a Z-Source Inverter Based Dynamic Voltage Restorer

arrow_icon

Abolfazl Kazemdehdashti, Ali Reza Seifi, Amin Shabanpoor Haghighi

arrow_icon

DOI: 10.15598/aeee.v11i3.782

Abstract

In this paper, dynamic voltage restorer (DVR) compensation methods are compared to each other for the load side connected shunt converter topology of z-source inverter based DVR to choose the best method. Four different topologies are recognized for DVR that two of them have energy storage devices, and two topologies have no energy storage that take ener-gy from the grid during the period of compensation. Here the load side connected shunt converter topology that takes necessary energy from the grid is used. Pre-sag compensation, in-phase compensation, energy-optimized methods are the three DVR compensation methods that studied and compared. A deep analysis through different diagrams would show the advantages or disadvantages of each compensation method. Equations for all methods are derived and the characteristics of algorithms are compared with each other. The simulation results done by SIMULINK/ MATLAB shows compensating by this topology based on the compensation methods.